Learn how to integrate SimPad with SimCapture to start recording sessions, capture simulation logs, and store data automatically for debriefing and review.

Written by Jeri Ellis

Updated at May 14th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
To find the contact information for your local office please visit:

Laerdal Customer Service

Table of Contents

Audience and Prerequisites What You’ll Accomplish Integration Workflow What Happens Next? Helpful Notes Need Help? What’s Next?
  • SimCapture Cloud Release Notes
    Release Notes Archive
  • SimCapture Cloud Administrator and Faculty Help
    SimCapture Cloud Getting Started SimCapture Cloud Tutorials SimCapture Cloud Troubleshooting
  • SimCapture Cloud Learner Help
  • SimCapture On-Premise Help
    SimCapture On-Premise Release Notes SimCapture On-Premise Migration tool SimCapture On-Premise Enterprise SimCapture On-Premise Pro SimCapture On-Premise Enterprise with Exam System SimCapture On-Premise Use Cases SimCapture On-Premise Getting Started
  • SimCapture for Skills Help
    SimCapture for Skills Administration Documentation SimCapture for Skills Student Documentation SimCapture for Skills Use Cases SimCapture for Skills Tutorial Videos
  • SimCapture Mobile Camera App
  • SimCapture Companion Apps Help
  • SimCapture Integrations Help
  • Samaritan AI Help
    Evaluation Builder Session Video Transcription
  • SimCapture Cloud Use Cases
    Enterprise Cloud Use Cases Pro Cloud Use Cases
  • Hardware and Network Technical Information Help
  • Glossary
+ More

This article walks you through how to integrate SimPad with SimCapture to capture session data, video, and logs during a simulation. The steps begin from the SimPad Home page and assume you are already familiar with basic SimPad functionality.

Use this workflow when you want SimPad‑driven simulations to be automatically recorded and logged in SimCapture for review, debriefing, and reporting.

Audience and Prerequisites

This guide is intended for:

  • Instructors, simulation technologists, or administrators who use SimPad with SimCapture
  • Users with permission to create and record sessions in SimCapture

Before you begin, confirm that:

  • You are familiar with SimPad’s basic operation
  • You have access to SimCapture and an available recording location
  • SimPad and SimCapture are connected to the appropriate network

What You’ll Accomplish

By completing this workflow, you will:

  • Start a session from SimPad
  • Configure SimCapture recording from within SimPad
  • Capture simulation logs and data directly into a SimCapture session

Integration Workflow

Step 1: Select Manual Mode

From the SimPad Home page, select Manual Mode.

Delete

You may see a warning about offline cameras if some devices are not powered on. This is expected behavior. Select OK to proceed.

Step 2: Name the Session

Enter a   descriptive session name .
This name will carry over to the SimCapture session for easier identification later.

Step 3: Open Session Settings

Select Session Settings , then choose Configure SimCapture .

This connects the SimPad session to SimCapture.

Step 4: Select a Location

Choose the SimCapture location where the session will be recorded. Only online locations appear in the list.

Step 5: Choose Camera Feeds

Select the camera feeds you want to include in the session, then select OK .

Step 6: Return to the Session Overview

Select Back twice to return to the session information page.

When prompted, select OK to continue.

Step 7: Start Recording

Select Start .

  • The SimCapture session begins recording
  • Session data and logs are captured automatically

Step 8: End the Session

When the simulation is complete:

  1. Select End
  2. Select Quit

The session stops, and all logs and recordings are saved to SimCapture.

What Happens Next?

After the session ends:

  • A SimCapture session is automatically created
  • All logs, data, and recordings are stored with the session
  • Authorized users can review the session from SimCapture for debriefing, evaluation, or reporting

Helpful Notes

  • Offline camera warnings at session start are normal if devices are powered off
  • The SimPad session and SimCapture session remain linked throughout recording
  • Session names entered in SimPad help identify recordings later in SimCapture

Need Help?

If the SimCapture session does not start, cameras do not appear, or logs are missing:

  • Verify the selected location is online
  • Confirm camera devices are powered on
  • Contact your System Administrator or Laerdal Support for assistance

What’s Next?

After integrating SimPad with SimCapture, common next steps include:

  • Debriefing recorded sessions
  • Reviewing event logs and data
  • Adding annotations or evaluations in SimCapture
simpad online locations camera selection configure simcapture session settings session setup manual mode simpad integration simcapture session start session end session logs simulation session simcapture session simulation integration simpad home page simulation workflow simulation recording simulation data session configuration integrating simpad with simcapture simpad simcapture integration simpad recording simcapture simulation recording workflow simcapture integrations simpad session recording simcapture session logs live simulation capture laerdal simpad simcapture

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • SimCapture Enterprise: Integrating and Running Sessions with LLEAP
  • SimCapture On Premise LLEAP Integration

Country and Language selector

Americas

  • América Latina (Español)
  • Brasil
  • Canada
  • USA

Asia / Pacific

  • Australia
  • China - 简体中文
  • Hong Kong
  • India
  • Japan - 日本
  • Korea - 한국어
  • Malaysia
  • New Zealand
  • Singapore (English)

Europe

  • België (Nederlands)
  • Belgique (Français)
  • Danmark
  • Deutschland
  • España
  • France
  • Italia
  • Nederland
  • Norge
  • Österreich
  • Polska
  • Schweiz
  • Suomi
  • Sverige
  • United Kingdom

Location not listed?

  • International (English)
Top
  • Products

    • Simulation & Training
    • Skills Proficiency
    • Courses & Learning
    • Medical Devices
  • Services

    • Educational Services
    • Technical Services
    • Resuscitation Quality Improvement
    • NESTLED
  • Insights

    • Events
    • SUN
  • Support

    • Contact Us
    • Customer Service
    • Product Catalogue
    • Product Downloads
    • Product Support & FAQs
  • About Us

    • One Million Lives - Our shared goal for 2030
    • Impact Update - Laerdal report on sustainability
    • Working at Laerdal
    • Our Partners
  • Facebook
  • Twitter
  • YouTube
  • Privacy Policy
  • Terms of Use
  • Sitemap
  • Whistleblower Channel
Copyright © 2022 Laerdal Medical. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Definition by Author

0
0
Expand