SimCapture Cloud Hardware Installation Requirements

Learn about the hardware requirements for successful installation of SimCapture Cloud.

Written by Adam Attinello

Updated at April 9th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
To find the contact information for your local office please visit:

Laerdal Customer Service

Table of Contents

Introduction Networking Simulation Center VLAN General Bandwidth Requirements Upload Download Inter-VLAN Outgoing Internet Connections Improving Live Video Connections WebRTC Turn Server Outgoing Port Information Internal Simulation Center VLAN SimCapture Connected Equipment on Simulation Center VLAN Client Furnished Equipment on SIMULATION CENTER VLAN Dante VLAN (Turnkey Only) Inter-VLAN Routing (SIMULATION VLAN and Dante VLAN) AV Devices on Dante VLAN Dante VLAN Switch Requirements Remote Support Access Sample Network Diagrams Typical Network Drop and Power Requirements Standard AV Package Advanced AV Package Control Room Additional Fixed Camera Additional PTZ Camera Hallway Paging Headphone Station Package Pillow Speaker Package Voice Changer Package Confederate Microphone Package
  • SimCapture Cloud Release Notes
  • SimCapture Cloud Administrator and Faculty Help
    SimCapture Cloud Getting Started SimCapture Cloud Tutorials SimCapture Cloud Troubleshooting
  • SimCapture Cloud Learner Help
  • SimCapture On-Premise Help
    SimCapture On-Premise Release Notes SimCapture On-Premise Migration tool SimCapture On-Premise Enterprise SimCapture On-Premise Pro SimCapture On-Premise Enterprise with Exam System SimCapture On-Premise Use Cases SimCapture On-Premise Getting Started
  • SimCapture for Skills Help
    SimCapture for Skills Administration Documentation SimCapture for Skills Student Documentation SimCapture for Skills Use Cases SimCapture for Skills Tutorial Videos
  • SimCapture Mobile Camera App Help
  • SimCapture Companion Apps Help
  • SimCapture Cloud Use Cases
    Enterprise Cloud Use Cases Pro Cloud Use Cases
  • Integrations Help
  • Hardware and Network Technical Information Help
  • Glossary
+ More

Introduction

As part of your SimCapture Cloud purchase and outlined in your services agreement a project manager will contact you to begin planning your installation. This will include reviewing all installation requirements, networking requirements, and a site readiness survey before installation begins.  

Our SimCapture Cloud AV products include cameras, microphones, and audio modules and may include speakers, amplifiers, and digital signal processors for use in recording and paging (when control station packages are purchased). Most of these devices use PoE and PoE+ (802.11af & 801.11at) and the client providing the network is responsible for providing switches capable of providing PoE+ and enough wattage to support all devices. 

To allow for a stable connection from the Customer’s network to the SimCapture Cloud servers, a minimum of a one Gigabyte (1GB) uplink is strongly recommended.

For basic SimCapture Cloud communication, outgoing internet access must be allowed from the Capture Nodes (the recording device) internal network to *.simcapture.com (443 TCP, 5000-5100 TCP/UDP) and *.amazonaws.com (443 TCP). More detailed information is found below.  

Note: You may need to reference purchased equipment to understand specific network requirements. Please consult with your project manager or support.

Networking

If the advanced audio package with the control station or headphone package is purchased, you are expected to provision 2 VLANs: a primary VLAN referred to as SIMULATION CENTER VLAN and an audio only VLAN referred to as the Dante VLAN. 

If you did not purchase an Advanced Package (ADV) with the control or headphone package, then only the SIMULATION CENTER-VLAN requirements are needed and the inter-VLAN SIMULATION CENTER/Dante routing section is N/A for your site. Your site only needs 1 VLAN.

Simulation Center VLAN

General Bandwidth Requirements

Upload

When a simulation starts recording, every configured video feed (~1500 kb/s), is uploaded to the cloud service and to any number of Live streaming viewers external of the Simulation VLAN per recording node: 

Download

Any previously recorded simulation debriefs will be downloaded from the cloud service. A stable connection to the cloud services is strongly recommended for seamless playback. 

Inter-VLAN Outgoing Internet Connections

SimCapture Cloud services are hosted on Amazon Web Services (AWS) – any devices interacting with SimCapture will need to be able to communicate with those services over HTTP (443/TCP). Additionally, live viewing of video requires webRTC (5000-5100/UDP/TCP). Whitelisting by FQDN/IP address is not recommended as these may change within the AWS infrastructure.

All connections from SimCapture Cloud are outgoing and never require incoming internet access. 

Improving Live Video Connections

On particularly complex networks with very severe restrictions. On particularly complex networks with very severe restrictions ephemeral TURN relay ports between 49152 and 65535 UDP may be required to view live video.. These are necessary only when a live viewer is not able to make a peer-to-peer connection directly with a CaptureNode. Relay connections are higher latency and lower quality, so IT teams should attempt to update their network configuration to facilitate this peer-to-peer connection. If this is not possible, the ephemeral relay ports are required to view live video.

Peer-to-peer video sessions can be established via multiple pathways (a core feature of WebRTC):

"Host" Connection

A "host" connection is a simple direct peer-to-peer connection via the devices local IP address. The following changes may help facilitate this type of connection:

  • Put CaptureNode and monitoring station on same VLAN/subnet
  • Enable Multicast on the network (WebRTC uses mDNS for enhanced privacy)
  • Open the ephemeral ports (49152-65535) inbound on the CaptureNode
  • Ensure the CaptureNode is directly reachable by IP address from the monitoring station

"Reflexive" Connection

A "reflexive" connection is a peer-to-peer connection established by way of hole punching when the other peer is not directly accessible by IP. It requires access to a STUN and/or TURN server to begin the hole punching process. The following changes may help facilitate this type of connection:

  • Ensure there is no Symmetric NAT between the CaptureNode and monitoring station
  • Open port 3478 inbound on the CaptureNode for access to the onboard STUN server
  • Open ports 5000-5100 outbound on the CaptureNode and monitoring station for access to the TURN server


If the above changes still do not resolve live video issues, open the ephemeral ports (49152-65535) outbound to the TURN server to guarantee relay connections can be established.


Inter-VLAN Outgoing Internet Connections

Port/Protocol Source Destination Purpose
443 TCP Capture Node *.simcapture.com Connection To SimCapture Cloud
443 TCP Control, Debrief, SP, Student, Monitor Workstations *.simcapture.com Access To SimCapture Cloud
3478 UDP/TCP
(Legacy as of July 15, 2023)
Capture Node *.simcapture.com Sending Live Video
3478 UDP/TCP
(Legacy as of July 15, 2023)
Control, Debrief, SP, Student, Monitor Workstations *.simcapture.com Viewing Live Video
443 TCP Capture Node *.amazonaws.com Upload Of Recorded Video
Delete


WebRTC Turn Server Outgoing Port Information

us-east-1 (US & Latin/South America)

Hostname IP Address Port(s) Protocol Purpose
turn.us-east-1.simcapture.com 

52.223.44.95 5000-5100 TCP/UDP Live video (TURN servers)
turn.us-east-1.simcapture.com  52.223.44.95 49152-65535 UDP WebRTC Relay Ports (optional, see note above)
platform.us-east-1.simcapture.com 

13.248.201.86 443 TCP SimCapture microservices (WebRTC signalling, future microservices) 

Delete

ca-central-1 (Canada)

Hostname IP Address Port(s) Protocol Purpose
turn.ca-central-1.simcapture.com

13.248.196.69 5000-5100 TCP/UDP Live video (TURN servers)
turn.ca-central-1.simcapture.com
13.248.196.69

49152-65535

UDP

WebRTC Relay Ports (optional, see note above)
platform.ca-central-1.simcapture.com

75.2.46.89 443 TCP SimCapture microservices (WebRTC signalling, future microservices)


Delete

eu-central-1 (EU and UK)

Hostname IP Address Port(s) Protocol Purpose
turn.eu-central-1.simcapture.com

75.2.93.103 5000-5100 TCP/UDP
Live video (TURN servers)
turn.eu-central-1.simcapture.com
75.2.93.103

49152-65535

UDP

WebRTC Relay Ports (optional, see note above)
platform.eu-central-1.simcapture.com

52.223.25.121 443 TCP SimCapture microservices (WebRTC signalling, future microservices) 

Delete

ap-southeast-2 (Sydney)

Hostname Address Port(s) Protocol Purpose
turn.ap-southeast-2.simcapture.com

75.2.17.88 5000-5100 TCP/UDP Live video (TURN servers)
turn.ap-southeast-2.simcapture.com
75.2.17.88

49152-65535

UDP

WebRTC Relay Ports (optional, see note above)
platform.ap-southeast-2.simcapture.com

99.83.170.55 443 TCP SimCapture microservices (WebRTC signalling, future microservices) 
Delete

ap-northeast-2 (South Korea)

Hostname Address Port(s) Protocol Purpose
turn.ap-northeast-2.simcapture.com

75.2.32.121 5000-5100 TCP/UDP Live video (TURN servers) 
turn.ap-northeast-2.simcapture.com
75.2.32.121

49152-65535

UDP WebRTC Relay Ports (optional, see note above)

platform.ap-northeast-2.simcapture.com
3.33.226.2 443 TCP SimCapture microservices (WebRTC signalling, future microservices) 

Delete


Internal Simulation Center VLAN

The Simulation Center VLAN connects all cameras, audio modules, and capture nodes. This VLAN is used to transmit the video and data streams from the cameras and audio modules to the capture nodes for recording. The capture nodes process, encode, and transmit the data for live viewing and storage.

Internal Simulation Center VLAN

Application Port/Protocol Source Destination Use
SimCapture Software 554 TCP/UDP

Capture Node

Audio Modules and Cameras RTSP Audio and Video Streams
SimCapture Multiplexer 443 TCP Control, Multiplex Workstations Cameras Optional Product: To view/control cameras in a grid configuration. 
SimCapture Paging Application 554 TCP/UDP Paging Workstations Audio Modules Optional Product: For software-based paging without the advanced audio option. 
LLEAP Screen Capture 6682 TCP Capture Node Patient Monitor Optional Product: For Recording Laerdal Patient Monitors
SimCapture 3478 TCP/UDP Monitoring Stations/Live Viewers CaptureNode WebRTC STUN ports for live video
Delete


SimCapture Connected Equipment on Simulation Center VLAN

SimCapture Connected Equipment on Simulation Center VLAN

Device IP Address Network Type Network Port Notes Used For
SimCapture Capture Node DHCP, DCHP reservation or Static Ethernet 1x 1000 BaseT Network drop 
Local device used to capture the local Simulations
IP Camera DHCP, DCHP reservation or Static

PoE

(PoE+ is possible)


1x 1000 BaseT Network drops with PoE (12.95w) If configured with DHCP, the camera must be connected with its hostname, not via an IP address. Video Capture device
Audio Module DHCP, DCHP reservation or Static PoE 1x 1000 BaseT Network drop with PoE (15.4w)

If configured with DHCP, the audio module must be connected with its hostname, not via an IP address. Analog Audio input to IP Encoder

Symetrix DSP Ethernet Port 1 (Turnkey Only)
PoE+ 
(No Cisco uPoE)*
1x 1000 BaseT Network drops with PoE+ (25.5w) The DSP is on the SIMULATION CENTER VLAN if NO control station or headphone package was purchased. Audio processor to mix and process multiple audio capture devices (Microphones)
Simulator Instructor PC DHCP, DCHP reservation or Static

Ethernet


1x 1000 BaseT Network drop  Must be physically connected even if in wireless mode. E.g. LLEAP Instructor Laptop
Simulated Patient Monitor PC DHCP, DCHP reservation or Static

Ethernet/ Wireless


1x 1000 BaseT Network drop  If an HDMI capture device is not being used to record the feed, then this device must be physically connected to the network even if in wireless mode for communication with SimCapture; even if in wireless mode for communication with the manikin. E.g. LLEAP Patient Monitor PC displaying simulated vitals
Delete


Client Furnished Equipment on SIMULATION CENTER VLAN

Client Furnished Equipment on SIMULATION CENTER VLAN

Device IP Address Network Type Notes

Control PC

DHCP

Ethernet

 

Multiplex PC

DHCP

Ethernet

To view/control cameras in a grid configuration. 

Debrief PC

DHCP

Ethernet

 

Student PC

DHCP reservation or Static IP

Ethernet

SimCapture Enterprise w/ CCM only

Standardized Patient PC

Ethernet

SimCapture Enterprise w/ CCM only

Monitor Station PC

Ethernet

SimCapture Enterprise w/ CCM only

Delete


Dante VLAN (Turnkey Only)

The Dante VLAN (D-VLAN) connects all Digital Signal Processors (DSP) and Dante audio amplifiers for real-time audio transmission over ethernet without the need to run extra audio cabling. This is used for in-room and hallway paging. 

The workflow starts at the control station microphones: > DSP > in-room Dante amplifiers > speaker. The DSP takes the analog microphone signal, processes it, and transmits it over UDP to the amplifiers, which then send the amplified analog signal to the speakers.  

This setup can also be used to transmit a copy of the audio (from the room microphones) to the control station headphones to provide low-latency monitoring audio.    

*The Dante VLAN is only required when SIMULATION CENTER control room(s), headphone station package(s) or Hallway Paging package(s) are purchased.*


Inter-VLAN Routing (SIMULATION VLAN and Dante VLAN)

Inter-VLAN Routing (SIMULATION VLAN and Dante VLAN)

Application Port Protocol Source  Destination Use
Dante Controller 8800, 8700-8706 UDP Multicast Dante Controller computer All Dante devices Monitor Dante devices

319,320 UDP, PTP All Dante devices All Dante devices
Clock sync

5353 UDP, MDNS Dante Controller computer
All Dante devices
Device info

4440, 4444, 4455 UDP

Dante Controller computer
Dante DSP's and Amplifiers Dante Routing

4321 UDP Multicast
Dante DSP's and Amplifiers
All Dante devices
Audio Broadcast

14336 - 14600 UDP Dante DSP's and Amplifiers
Dante DSP's and Amplifiers
Audio Unicast

Symetrix Composer


49216 UDP, Multicast Dante Controller computer All Dante devices Broadcast packet to local hardware.

Symetrix Composer

49184, 49344 

UDP

D-VLAN Dante DSPs and Amplifiers 

SIMULATION-VLAN

Control and meter feedback, Channel Names 

Symetrix Composer

8000, 49472, 59472 

UDP

Control Workstations 

D-VLAN DSP’s and Amplifiers 

SymNet Communications, Routing 

Symetrix Composer

21 

FTP SIMULATION-VLAN

D-VLAN DSP’s and Amplifiers 

Firmware Updates 

Symetrix Composer

48631

TCP SIMULATION-VLAN

D-VLAN DSP’s and Amplifiers

Remote Terminal

Delete


AV Devices on Dante VLAN

All Dante devices require DHCP with MAC address reservation (preferred) or Static IPs.

AV Devices on Dante VLAN

Device Network Type Notes
In-Room Stewart Amplifier PoE+

No CDP*



In-Room Symetrix DSP - Ethernet Port 1
PoE+

No CDP*

This is configured on the Dante VLAN if a control station or headphone package exists.



In-Room Symetrix DSP - Dante Port 1
Ethenet
Control Room Symetrix DSP - Ethernet Port 1 PoE+

No CDP*


Control Room Symetrix DSP - Dante Port 1 Ethernet

 

*If you are experiencing PoE negotiation issues with Cisco Switch, verify that the LLDP is enabled.  This is the protocol that negotiates PoE and it is disabled by default in Cisco products. In addition, PoE+ on Cisco products has three additional separate command sets, one sets max PoE per port at the site, one sets the max budget for the switch, and a final is called “Cisco two event classification” and handles delivered PoE wattage.*


Delete


Dante VLAN Switch Requirements

Dante VLAN Switch Requirements

Configuration Setting Value Notes
Energy Efficiency Ethernet Disabled This will cause the DSP and Amp devices to go offline.
IGMP Filtering Disabled Dante uses multicast for discovery and Precision Time Protocol to sync clocks.
QoS DSCP with strict priority. Used to prioritize Dante traffic to reduce latency and jitter.
VPN Dante VLAN The IP assigned after a VPN connection is made must be on the Dante VLAN. This allows Dante Controller to diagnose/update the Dante configuration.
*We highly recommend all devices on the Dante VLAN be on the same physical switch. Failure to complete the above could manifest as clicks, pops, and dropouts of audio transmissions.*
Delete

Remote Support Access

Remote support access, such as VPN access, Go2Assist, RemotePC, or another remote access option is required and must be provided to both networks for remote SimCapture and AV support. Without access, support may be delayed or unavailable.

*The VPN connection must provide an IP address within the same subnet as the Dante VLAN - if applicable*

Sample Network Diagrams

SimCapture Cloud with ADV+STD AV & Software Paging 
North-Latin-South America
SimCapture Cloud ADV AV+STD AV & Hardware Paging
North-Latin-South America

Typical Network Drop and Power Requirements

The following are typical network and power requirements for each package. Your exact number of connections may vary based on the products purchased. 

  • All Ethernet connection types are assumed to be 1000 BaseT Gigabit Ethernet.
  • Some PCs outline below are Customer Furnished Equipment (CFE).
  • Some sections are not applicable (N/A) for each device.


Standard AV Package

Standard AV Package

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Axis Audio Module 1 PoE Simulation Optional Includes 120/220VAC Power adapter
Axis PTZ Cameras 2 PoE Simulation N/A
Stewart Audio Amp 1 PoE+ Dante N/A
SimCapture Node 1 N/A Simulation Required - 1.5 amps Includes 120/220VAC Power adapter

HDMI to IP Capture 1 N/A Simulation Required - 1 amp Includes 120/220VAC Power adapter


Delete


Advanced AV Package

Advanced AV Package

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Axis Audio Module 1 PoE Simulation Optional Includes 120/220VAC Power adapter
Axis PTZ Cameras 2 PoE Simulation N/A
Stewart Audio Amp 1 PoE+ Dante N/A
Symetrix DSP 1 PoE+ Simulation N/A DSP will be connected to both VLANs via separate ports
1 N/A Dante
SimCapture Node 1 N/A Simulation Required - 1.5 amps Includes 120/220VAC Power adapter

HDMI to IP Capture 1 N/A Simulation Required - 1 amp Includes 120/220VAC Power adapter



Control Room

Control Room

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Symetrix DSP 1 PoE+ Simulation N/A DSP will be connected to both VLANs via separate ports.
1 N/A Dante
CFE Control PC 1
N/A

Simulation

If Applicable CFE Control Station PC to Start, Stop and Annotate Sessions. (Optional but recommended)
CFE Multiplex PC 1
N/A

Simulation

If Applicable CFE PC to display IP cameras in a multiplex view. (Optional but recommended)
Delete


Additional Fixed Camera

Additional Fixed Camera

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Fixed IP Camera 1 PoE Simulation N/A
Delete


Additional PTZ Camera

Additional PTZ Camera

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
PTZ IP Camera 1 PoE Simulation N/A
Delete


Hallway Paging

Hallway Paging

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Stewart Speaker Amp 1 N/A Dante 120VAC


Delete


Headphone Station Package

Headphone Station Package

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Headphone Amp 1 PoE+ Dante N/A


Delete


Pillow Speaker Package

Pillow Speaker Package

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Stewart Speaker Amp 1 PoE+ Dante N/A


Delete


Voice Changer Package

Voice Changer Package

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
Voice Changer 0

120VAC to USB


Delete


Confederate Microphone Package

Confederate Microphone Package

Device Network Port Requirements Main Power Notes
Qty PoE or PoE+ VLAN
RDL RU-MLB2P 1 PoE Dante N/A
2x Wireless Mic bases 0

2x120VAC


Delete



network vlan port hardware install dante installation simulation

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Registering and using the LLEAP plugin with SimCapture Cloud
  • Connection and port requirements
  • SimCapture Enterprise with Exam System: An introduction to single sign-on in SimCapture

Country and Language selector

Americas

  • América Latina (Español)
  • Brasil
  • Canada
  • USA

Asia / Pacific

  • Australia
  • China - 简体中文
  • Hong Kong
  • India
  • Japan - 日本
  • Korea - 한국어
  • Malaysia
  • New Zealand
  • Singapore (English)

Europe

  • België (Nederlands)
  • Belgique (Français)
  • Danmark
  • Deutschland
  • España
  • France
  • Italia
  • Nederland
  • Norge
  • Österreich
  • Polska
  • Schweiz
  • Suomi
  • Sverige
  • United Kingdom

Location not listed?

  • International (English)
Top
  • Products

    • Simulation & Training
    • Skills Proficiency
    • Courses & Learning
    • Medical Devices
  • Services

    • Educational Services
    • Technical Services
    • Resuscitation Quality Improvement
    • NESTLED
  • Insights

    • Events
    • SUN
  • Support

    • Contact Us
    • Customer Service
    • Product Catalogue
    • Product Downloads
    • Product Support & FAQs
  • About Us

    • One Million Lives - Our shared goal for 2030
    • Impact Update - Laerdal report on sustainability
    • Working at Laerdal
    • Our Partners
  • Facebook
  • Twitter
  • YouTube
  • Privacy Policy
  • Terms of Use
  • Sitemap
  • Whistleblower Channel
Copyright © 2022 Laerdal Medical. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Definition by Author

0
0
Expand