Connection and port requirements

Learn about the different network connection and port requirements for various software and hardware products.

Written by Jeri Ellis

Updated at December 19th, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
To find the contact information for your local office please visit:

Laerdal Customer Service

Table of Contents

New Changes as of May 1, 2023 Things to know before you begin Advanced networking and port requirements Outgoing internet connections May 2023: New outbound addresses and ports required for live video Internal network port requirements Advanced audio package - Dante
  • SimCapture Cloud Release Notes
  • SimCapture Cloud Administrator and Faculty Help
    SimCapture Cloud Getting Started SimCapture Cloud Tutorials SimCapture Cloud Troubleshooting
  • SimCapture Cloud Learner Help
  • SimCapture On-Premise Help
    SimCapture On-Premise Release Notes SimCapture On-Premise Migration tool SimCapture On-Premise Enterprise SimCapture On-Premise Pro SimCapture On-Premise Enterprise with Exam System SimCapture On-Premise Use Cases SimCapture On-Premise Getting Started
  • SimCapture for Skills Help
    SimCapture for Skills Administration Documentation SimCapture for Skills Student Documentation SimCapture for Skills Use Cases SimCapture for Skills Tutorial Videos
  • SimCapture Mobile Camera App Help
  • SimCapture Companion Apps Help
  • SimCapture Cloud Use Cases
    Enterprise Cloud Use Cases Pro Cloud Use Cases
  • Integrations Help
  • Hardware and Network Technical Information Help
  • Glossary
+ More

New Changes as of May 1, 2023

As of May 1, 2023, new outbound ports and addresses will be required for Live video streaming. See the New outbound addresses and ports required section for more information.

 

If you are a new customer, as part of your SimCapture Cloud purchase and outlined in your services agreement, a member of Laerdal support will contact you to begin planning your installation. This will include reviewing all installation and networking requirements as well as a site readiness survey before installation begins.

If you are an existing customer, please make your IT team aware of the information in this article so they can assist you in ensuring your SimCapture installation continues to meet network requirements.

Things to know before you begin

Our SimCapture Cloud AV products include cameras, microphones, and audio modules and may include speakers, amplifiers, and digital signal processors for use in recording and paging (when control station packages are purchased). Most of these devices use PoE and PoE+. The client providing the network is responsible for providing switches capable of providing PoE+ and enough wattage to support all devices. 

Note: Refer to the original manufacturers documentation for more detailed requirements. 

SimCapture Cloud recommends a minimum of one Gigabit (1Gb) uplink from the Customer’s internet work to be available for connecting the Customer’s network to the SimCapture Cloud services.

IMPORTANT: Please contact the Support team before closing Port 3478.

Advanced networking and port requirements

More detailed and advanced hardware and networking requirements may be found in SimCapture Cloud Hardware Installation Requirements.

Outgoing internet connections

  • SimCapture Cloud services are hosted on Amazon Web Services (AWS). Devices interacting with SimCapture will need to communicate with those services over HTTP (443/TCP).
  • Live viewing of video requires webRTC (5000-5100/UDP/TCP, formerly 3478).
  • Whitelisting by FQDN/IP address is not recommended as these may change within the AWS infrastructure.
  • All connections from SimCapture Cloud are outgoing and never require incoming internet access.

 

Port Protocol Source Destination Purpose
443 TCP Capture node *.simcapture.com Connection to SimCapture Cloud
443 TCP Control, Debrief, SP, Student, Monitor workstations *.simcapture.com Access to SimCapture Cloud
3478 UDP/TCP Capture node *.simcapture.com Sending live video (No longer necessary after July 15th, 2023)
3478 UDP/TCP Control, Monitor workstations *.simcapture.com Viewing live video (No longer necessary after July 15th, 2023)
5000-5100 UDP/TCP Capture node *.simcapture.com Sending live video
5000-5100 UDP/TCP Control, Monitor workstations *.simcapture.com Viewing live video
443 TCP Capture node *.amazonaws.com Upload of recorded video
443 TCP Debrief *.cloudfront.net Debriefing of previously recorded video

May 2023: New outbound addresses and ports required for live video

All communication with SimCapture is outbound from the client network. For further information on the purposes of these changes, see the More Information section further along in the document. 

us-east-1 (US & Latin/South America)

Hostname IP Address Port(s) Protocol Purpose
turn.us-east-1.simcapture.com 52.223.44.95 5000-5100 TCP/UDP Live video (TURN servers)
platform.us-east-1.simcapture.com 13.248.201.86 443 TCP SimCapture microservices (WebRTC signalling, future microservices)
 
 

ca-central-1 (Canada)

Hostname IP Address Port(s) Protocol Purpose
turn.ca-central-1.simcapture.com 13.248.196.69 5000-5100 TCP/UDP Live video (TURN servers)
platform.ca-central-1.simcapture.com 75.2.46.89 443 TCP SimCapture microservices (WebRTC signalling, future microservices)
 
 

eu-central-1 (EU and UK)

Hostname IP Address Port(s) Protocol Purpose
turn.eu-central-1.simcapture.com 75.2.93.103 5000-5100 TCP/UDP Live video (TURN servers)
platform.eu-central-1.simcapture.com 52.223.25.121 443 TCP SimCapture microservices (Web RTC signalling, future microservices)
 
 

ap-southeast-2 (Sydney)

Hostname IP Address Port(s) Protocol Purpose
turn.ap-southeast-2.simcapture.com 75.2.17.88 5000-5100 TCP/UDP Live video (TURN servers)
platform.ap-southeast-2.simcapture.com 99.83.170.55 443 TCP SimCapture microservices (WebRTC signalling, future microservices)
 
 

ap-northeast-2 (Seoul)

Hostname IP Address Port(s) Protocol Purpose
turn.ap-northeast-2.simcapture.com 75.2.32.121 5000-5100 TCP/UDP Live video (TURN servers)
platform.ap-northeast-2.simcapture.com 3.33.226.2 443 TCP SimCapture microservices (WebRTC signalling, future microservices)
 
 

Internal network port requirements  

The Capture Node device will need to make connections on your internal network to the audio-visual equipment. It is recommended that static IPs or reserved internal hostnames are used for these devices.  

Application Port Protocol Source Destination Use
SimCapture software 554 TCP/UDP Capture node Audio modules and cameras RTSP audio and video streams
SimCapture multiplexer 443 TCP Control, Multiplex workstations Cameras Optional Product: To view/control cameras in a grid configuration
SimCapture paging application 554 TCP/UDP Paging workstations Audio modules Optional product: For software-based paging without the advanced audio option
LLEAP screen capture 6682 TCP Capture node Patient monitor Optional product: For recording Laerdal patient monitors

Advanced audio package - Dante

Customers purchasing the advanced audio package with simulation control rooms or headphone stations package will have additional hardware and networking requirements.  It is suggested this equipment be placed on a separate VLAN with the following ports open between the new VLAN and your internal network. 

Application Port Protocol Source Destination Use
Symetrix composer 49216 UDP, Multicast Dante Controller computer All Dante devices Broadcast packet to local hardware.
Symetrix composer 49184, 49344 UDP D-VLAN Dante DSPs and amplifiers Internal network Control and meter feedback, Channel names
Symetrix composer 8000, 49472, 59472 UDP Control workstations D-VLAN DSPs and amplifiers SymNet communications, routing
Symetrix composer 21 FTP Simulation - VLAN D-VLAN DSPs and amplifiers Firmware updates
Symetrix composer 48631 TCP Simulation - VLAN D-VLAN DSPs and amplifiers Remote terminal

 

ports linkage link requirements port parameters net connectivity connection port connections simcapture-enterprise simcapture-pro simcapture-exam-system

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • SimCapture Cloud Hardware Installation Requirements
  • SimCapture Client Furnished Equipment (CFE) Specifications

Country and Language selector

Americas

  • América Latina (Español)
  • Brasil
  • Canada
  • USA

Asia / Pacific

  • Australia
  • China - 简体中文
  • Hong Kong
  • India
  • Japan - 日本
  • Korea - 한국어
  • Malaysia
  • New Zealand
  • Singapore (English)

Europe

  • België (Nederlands)
  • Belgique (Français)
  • Danmark
  • Deutschland
  • España
  • France
  • Italia
  • Nederland
  • Norge
  • Österreich
  • Polska
  • Schweiz
  • Suomi
  • Sverige
  • United Kingdom

Location not listed?

  • International (English)
Top
  • Products

    • Simulation & Training
    • Skills Proficiency
    • Courses & Learning
    • Medical Devices
  • Services

    • Educational Services
    • Technical Services
    • Resuscitation Quality Improvement
    • NESTLED
  • Insights

    • Events
    • SUN
  • Support

    • Contact Us
    • Customer Service
    • Product Catalogue
    • Product Downloads
    • Product Support & FAQs
  • About Us

    • One Million Lives - Our shared goal for 2030
    • Impact Update - Laerdal report on sustainability